Audiogram Plotter
Plot air and bone conduction hearing thresholds for both ears, mark masked and no-response results, and download the finished audiogram chart as an image.
🔒 This tool runs entirely in your browser. Your files are never uploaded to a server.
Right ear (dB HL)
Left ear (dB HL)
Symbol key
How Audiogram Plotter works
- Enter the air-conduction hearing threshold, in dB HL, for each ear at the six standard test frequencies (250 Hz to 8000 Hz). Optionally add bone conduction (tested at 250–4000 Hz) with the "Add bone conduction" checkbox for each ear.
- The chart redraws instantly on every change, plotting each ear as a connected line — right ear in red with O marks, left ear in blue with X marks, using the standard ASHA symbol set for masked results and bone conduction (see the symbol key below the chart).
- Check "No response" on any frequency tested to the audiometer's maximum with no response — the chart marks it with the standard 45-degree arrow instead of connecting it into the line.
- The frequency axis uses a logarithmic scale (matching a real clinical audiogram) so that equal-width columns represent equal octave steps, not equal Hz steps.
- Below the chart, each ear's average air-conduction threshold across the six frequencies is classified into a standard severity band, from Normal through Profound.
- Use "Download chart as PNG" to save the plotted chart as an image for records or sharing.
Reading the severity bands
The pure-tone average is classified as: 0–15 dB HL Normal, 16–25 dB HL Slight, 26–40 dB HL Mild, 41–55 dB HL Moderate, 56–70 dB HL Moderately severe, 71–90 dB HL Severe, and above 90 dB HL Profound. These bands follow the widely used clinical convention for describing pure-tone average hearing loss.
FAQ
What do the X and O symbols mean?
This follows the standard ASHA audiogram convention: red O marks are the right ear's air-conduction thresholds and blue X marks are the left ear's. Bone conduction adds a second symbol pair, < / > for unmasked and [ / ] for masked results, and masked air conduction switches to a triangle (right) or square (left) — the same convention used on a clinical audiogram printout. See the symbol key below the chart.
Why does the chart go from -10 at the top to 120 at the bottom?
Audiograms plot hearing level (dB HL) with quieter, better-heard sounds at the top and louder thresholds — meaning worse hearing — lower down, so a line that drifts downward visually shows hearing loss increasing, matching the standard clinical chart layout.
What does the "No response" checkbox do?
Check it when a frequency was tested up to the audiometer's maximum output with no response — the chart draws the standard 45-degree arrow attached to that symbol instead of connecting it into the threshold line, matching how audiologists mark an untestable threshold on a paper audiogram.
Why is bone conduction limited to 250–4000 Hz?
Bone-conduction oscillators can't reliably deliver frequencies above 4000 Hz, so clinical pure-tone audiometry only tests bone conduction at the octave frequencies from 250 Hz to 4000 Hz — this tool follows that same range.
Is this a substitute for a real hearing test?
No — this only visualizes numbers you already have (from an audiologist's report, for example) and estimates a severity band from the average. It cannot measure your hearing itself; use it to review or share results you already obtained from a proper pure-tone audiometry test.
How do I read the finished audiogram chart?
The horizontal axis is frequency (pitch), from 250 Hz on the left to 8000 Hz on the right, plotted on a logarithmic scale so each column is an equal octave step. The vertical axis is loudness in dB HL, running from quiet at the top (-10) to loud at the bottom (120) — so a line that sits lower means a louder sound was needed to hear it, i.e. worse hearing at that frequency.
What do the severity bands (Normal, Mild, Moderate, Severe) mean?
Each ear's average air-conduction threshold across the six standard frequencies is classified using the common clinical convention: 0-15 dB HL Normal, 16-25 Slight, 26-40 Mild, 41-55 Moderate, 56-70 Moderately severe, 71-90 Severe, and above 90 Profound. The tool computes and labels this average automatically below the chart for each ear.
How we compare
| Feature | Online Tool Store | Audiogram Creator | audprof.com Plotter | Hearing Aid Know |
|---|---|---|---|---|
| Air and bone conduction, both ears | ✓ | ✓ | ✓ | ✓ |
| Masked results (air and bone) | ✓ | ✓ | ✓ | ✓ |
| "No response" arrow marking | ✓ | Not shown | ✓ | Not shown |
| Download chart as an image | ✓ | ✓ | ✓ | ✓ |
| No file upload — runs entirely in your browser | ✓ | ✓ | ✓ | ✓ |
| No sign-up, no ads, no legacy plugin errors | ✓ | ✓ | ✓ | Browser-compatibility warning shown |
Audiogram Plotter now matches the leading online audiogram tools on air/bone conduction, masking, and image export, while adding a standard "no response" arrow marking that most of them skip — all without an upload, a sign-up, or the legacy browser warning one competitor still shows.